CompareBuyer accountFor factories ↗Request a quote

Grain processing

Guangchang TCXT Magnetic Cylinders and TCXP Magnetic Separators

Guangchang makes two permanent-magnet families for pulling iron out of feed, grain and flour streams. The TCXT cylinder comes in five sizes from TCXT15 to TCXT40, rated 10–100 t/h with a field of ≥3500GS. The TCXP magnetic separator comes in three sizes, TCXP30 to TCXP50, rated 5–15 t/h at >2500GS, and it is the only family with a printed removal rate (≥99%) and overall dimensions in mm. Neither needs a motor. Below are the capacity rows, the TCXP outlines, how cleaning works and what to put in a quote request.

Jiaxing Guangchang Machinery Co., Ltd. ↗

Build my procurement brief

What the magnets remove and where they sit

The TCXP sheet names ferromagnetic impurities as its target. The TCXT sheet describes iron removal from raw-material streams such as feed, grain and flour. Both are iron separators. Stones, non-magnetic metal and other foreign matter call for other cleaning stages. Guangchang covers those with the TQSX and TQSF gravity stoners and, for oversized debris, the TCQY63 drum pre-cleaner.

A historical FAO chapter on fish-feed plants puts a magnet near the loading hopper, so that iron pieces are caught before they reach later machines. That is a sensible general position for an iron-removal stage in any feed or grain line. Our grain cleaning and handling line basics guide places the magnet between the vibrating sieve and the destoner.

When you enquire, describe the material, the kind of iron you expect (bolts, wire, filings) with typical size and shape, where the magnet will go in the line and what the downstream machines can tolerate. Guangchang mentions several industries but publishes no material temperature range, particle-size limit or food-contact certificate, so ask for any of these you need.

Sources [1] [2] [4]

Published specifications

Read each value with its stated conditions, and ask the manufacturer for any limit not listed here.

SpecificationPublished valueMeaning / limit
TCXT family15, 20, 25, 30 and 40 [1]Five cylinder sizes on one sheet, each with its own capacity row.
TCXP family30, 40 and 50 [2]A separate separator design with its own table. TCXP30 and TCXT30 share a number but differ in form and capacity.
Magnetic fieldTCXT ≥3500GS; TCXP >2500GS [1] [2]Guangchang's field ratings. Ask where on the magnet the reading is taken.
TCXP removal rateFerromagnetic impurity removal ≥99% [2]Printed for TCXP only, with no feed, particle size or flow stated alongside it.
DrivePermanent magnets; no motive drive stated [1] [2]No motor or power supply for the magnet itself. Conveying and air handling belong to the rest of the line.

TCXT and TCXP capacity by model

Capacities are in t/h. The sheets do not say which material or bulk density they assume, so compare models within one family and give Guangchang your own material for a sizing answer.

ModelCapacity and field
TCXT1510–15 t/h; ≥3500GS.
TCXT2020–30 t/h; ≥3500GS.
TCXT2530–50 t/h; ≥3500GS.
TCXT3050–70 t/h; ≥3500GS.
TCXT4080–100 t/h; ≥3500GS.
TCXP305–8 t/h; >2500GS; removal ≥99%.
TCXP407–12 t/h; >2500GS; removal ≥99%.
TCXP5010–15 t/h; >2500GS; removal ≥99%.

Sources [1] [2]

Field strength, removal rate and materials

TCXT states a field level but no removal rate. TCXP states both. The two families differ in geometry and flow, so a stronger field on paper may or may not catch more iron in your line.

Published figureWhat to ask for
Field readingThe measurement point (surface or gap), the instrument and a current reading for the unit you buy.
Removal rateThe feed, impurity mix, sampling and calculation behind the TCXP ≥99% figure, or an agreed test on your material.
Comparing familiesA same-feed comparison if you are choosing between a TCXT cylinder and a TCXP separator.
Magnet and bodyTCXT is described as rare-earth permanent magnet in stainless construction; TCXP as NdFeB. Ask for the magnet grade, contact-surface finish and any material certificate.
Full cleaning lineNeither sheet covers screens or destoners. Specify those stages separately.

Sources [1] [2]

TCXP outline dimensions and TCXT drawings

The TCXP sheet gives overall dimensions in mm. The TCXT sheet gives none, and neither sheet lists weight or connection drawings.

Model, overall L×W×HInstallation notes
TCXP30: 620×360×355 mmRequest inlet and outlet connection details and the installed orientation.
TCXP40: 620×460×405 mmCheck space to open the unit for cleaning on your chute layout.
TCXP50: 640×560×455 mmAsk for machine and packed weight and the clearance needed to remove and inspect the magnet.
TCXT15–40Request an outline drawing in mm with connections for the size you choose.
Plant interfacesAsk Guangchang for the support method, feed distribution upstream and outlet route, plus any pressure, dust-zone or interlock data your plant needs.

Sources [1] [2]

Cleaning the magnet and handling collected iron

TCXT has a cleaning door; Guangchang describes TCXP as easy to maintain. Cleaning is manual on both sheets, with no interval or method printed, so plan the routine with the maker.

  1. Where iron collects

    Ask Guangchang to show where the iron is held and how clean product passes the magnet. Neither family has an automatic reject.

  2. Cleaning procedure

    Request the cleaning and inspection instructions, the access needed and how the unit is stopped and isolated before the door opens.

  3. Magnet condition

    Agree how each magnet is identified and how its strength is checked over time. No service life or remagnetising interval is published.

  4. Spare parts

    Keep part references for the magnet, housing, door seal and connections of the unit you buy.

Sources [1] [2]

Agreeing an acceptance test

If you need a removal figure for your plant, test the chosen model on your own material. Ask Guangchang for a safe test method suited to the installation.

ItemWhat to record
UnitFamily and model, magnet and housing, layout and field reading at the time of the test.
Test basisMaterial and impurity conditions, flow, quantity handled, and the sampling and calculation method.
ResultIron captured and downstream sample results for the agreed task, stated for that test alone.
PaperworkKeep the maker's capacity, field and removal figures alongside your own measured result, and ask for any certificate in writing.

Sources [1] [2] [4]

Buyer questions

Is TCXT30 the same capacity as TCXP30?

No. TCXT30 is rated 50–70 t/h and TCXP30 5–8 t/h. They are different designs that happen to share a number. [1] [2]

Will the ≥3500GS cylinder catch more iron than a TCXP?

Guangchang publishes no same-feed comparison or field measurement method. Ask for a test on your material if the choice matters. [1] [2]

How was the TCXP ≥99% removal rate measured?

The sheet gives the figure without a test method or material. Ask Guangchang to confirm the test basis in writing, or agree a test on your feed. [2]

Can I plan a TCXT installation from the TCXP dimensions?

No. Only TCXP has published dimensions. Request a current drawing for the TCXT size you choose. [1] [2]

Prepare a model-specific brief

Write your actual conditions below. This local worksheet is not sent, uploaded or saved after reload. Copy or print it before leaving.

Sources

Specifications come from the manufacturer's publications listed below, with the date each was checked.

  1. Official TCXT permanent-magnet cylinder sheet

    manufacturer · Checked 2026-10-12

    Five TCXT capacity rows from 10 to 100 t/h, field ≥3500GS, stainless body with rare-earth magnet and no drive.

  2. Official TCXP magnetic-separator sheet

    manufacturer · Checked 2026-10-12

    Three TCXP capacity rows from 5 to 15 t/h, field >2500GS, removal ≥99%, NdFeB magnets and overall dimensions in mm.

  3. Official cleaning-component catalogue

    manufacturer · Checked 2026-10-12

    Lists the magnetic separator and the permanent-magnet cylinder as separate cleaning components.

  4. FAO fish-feed chapter: upstream iron collection

    industry platform · Checked 2026-10-12

    Historical chapter by F. Majoros that places a magnet near the loading hopper to catch iron pieces before processing.

Report a correction through our contact form, quoting Guangchang TCXT Magnetic Cylinders and TCXP Magnetic Separators and the relevant specification.

Share this pageLinkedInXFacebookWhatsAppTelegramRedditEmail